(Methyl Ethyl Ketone)
1.1. Product identifier
Product Name: Butanone
| Article number: | 9001118 |
| CAS No: | 78-93-3 |
| EC No (EU Index No) | 201-159-0 |
| (606-002-00-3) | |
| REACH registration number: | 01-2119457290-43 |
1.2. Relevant identified uses of the substance or mixture and uses advised against
Product categories [PC]: PC9a – Coatings and paints, thinners, paint removers
PC 0.56 – Solvent
1.3. Details of the supplier of the safety data sheet
Supplier: pantocomo GmbH, Röntgenstr. 8, 76133 Karlsruhe, Germany
E-mail address info@pantocomo.de
1.4. Emergency telephone number
Emergency Telephone: +44 20 3885 0382 (CHEMTREC, 24h/7/365; CCN: 1012799)
CHEMTREC local:
| DE: 0800 1817059 | AT: +43 1 3649237 | CH: +41 435081970 |
| NL: +31 85 888 0596 | BE: +32 2 808 32 37 | FR: +33 9 75 18 14 07 |
| ES: +34 931768511 | PT: +351 308 801 773 | IT: +39 02 4555 7031 |
| DK: +45 69 91 85 73 | SE: +46 8 525 034 03 | FI: +358 9 42419014 |
| PL: +48 22 398 80 29 | CZ: +420 228 880 039 | SK: +421 2/330 579 72 |
| SI: +386 1 888 80 16 | HU: +36 1 808 8425 | RO: +40 376 300 026 |
| UK: +44 20 3807 3798 |
| Emergency Telephone – §45 – (EC)1272/2008 | |
| Austria | +43 1 406 43 43 (Giftinformationszentrale) |
| Bulgaria | +359 2 9154 213 (Pirogov) |
| Italy | Centro Antiveleni di Milano: 02.66101029; Centro Antiveleni di Roma: 06.3054343; Centro Antiveleni di Roma: 06.49978000; Centro Antiveleni di Roma: 06.68593726; Centro Antiveleni di Pavia: 0382.24444; Centro Antiveleni di Firenze: 055.7947819; Centro Antiveleni di Bergamo: 800.883300; Centro Antiveleni di Foggia: 0881.732326; Centro Antiveleni di Napoli: 081.7472870; Centro Antiveleni di Verona: 800.011.858 |
| Slovakia | +421 2 5477 4166 (NTIC) |
| Hungary | +36 80 201 199; +36 1 476 6464 (ETTSZ) |
2.1. Classification of the substance or mixture
Regulation (EC) No 1272/2008
| Flammable liquids | Category 2 – (H225) |
| Serious eye damage/eye irritation | Category 2 – (H319) |
| Specific target organ toxicity (single exposure) | Category 3 – (H336) Narcotic effects |
2.2. Label elements
Signal word: Danger
Hazard components for labeling:
Contains Methyl ethyl ketone
Hazard statements:
H225 – Highly flammable liquid and vapor. H319 – Causes serious eye irritation.
H336 – May cause drowsiness or dizziness.
EU Specific Hazard Statements:
EUH066 – Repeated exposure may cause skin dryness or cracking.
Precautionary Statements – EU (§28, 1272/2008):
P210 – Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking P261 – Avoid breathing dust/fume/gas/mist/vapors/spray
P312 – Call a POISON CENTER or doctor if you feel unwell
P370 + P378 – In case of fire: Use dry chemical, CO2, water spray or alcohol-resistant foam to extinguish P403 + P233 – Store in a well-ventilated place. Keep container tightly closed
P501 – Dispose of contents/ container to an approved waste disposal plant
2.3. Other hazards
PBT & vPvB: This substance does not meet the PBT/vPvB criteria of REACH, annex XIII.
Endocrine Disruptor Information: No information available
3.1 Substances
| Chemical name | CAS No | EC No (EU Index No) | REACH registration number | Classification according to Regulation (EC) No. 1272/2008 [CLP] | Weight-% |
| Methyl ethyl ketone | 78-93-3 | 201-159-0 | 01-2119457290-43 | Flam. Liq. 2 (H225) | 90 – 100 |
| (606-002-00-3) | Eye Irrit. 2 (H319) | ||||
| STOT SE 3 (H336) | |||||
| (EUH066) |
Acute Toxicity Estimate:
If LD50/LC50 data is not available or does not correspond to the classification category, then the appropriate conversion value from CLP Annex I, Table 3.1.2, is used to calculate the acute toxicity estimate (ATEmix) for classifying a mixture based on its components
| Chemical name | Oral LD50 mg/kg | Dermal LD50 mg/kg | Inhalation LC50 – 4 hour – dust/mist – mg/L | Inhalation LC50 – 4 hour – vapor – mg/L | Inhalation LC50 – 4 hour – gas – ppm |
| Methyl ethyl ketone 78-93-3 | 2194 | 5002 | No data available | 34 | No data available |
This product does not contain candidate substances of very high concern at a concentration >=0.1% (Regulation (EC) No. 1907/2006 (REACH), Article 59)
4.1. Description of first aid measures
General advice: Show this safety data sheet to the doctor in attendance.
Inhalation: Remove to fresh air. IF exposed or concerned: Get medical advice/attention.
Eye contact: Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep eye wide open while rinsing. Do not rub affected area. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists.
Skin contact: Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes.
Ingestion: Do NOT induce vomiting. Rinse mouth. Never give anything by mouth to an unconscious person. Call a physician.
Self-protection of the first aider: Remove all sources of ignition. Ensure that medical personnel are aware of the
material(s) involved, take precautions to protect themselves and prevent spread of contamination. Use personal protective equipment as required. See section 8 for more information. Avoid contact with skin, eyes or clothing.
4.2. Most important symptoms and effects, both acute and delayed
Symptoms May cause redness and tearing of the eyes. Burning sensation. Inhalation of high vapor concentrations may cause symptoms like headache, dizziness, tiredness, nausea and vomiting.
Effects of Exposure No information available.
4.3. Indication of any immediate medical attention and special treatment needed
Note to physicians: Treat symptomatically.
5.1. Extinguishing media
Suitable Extinguishing Media: Dry chemical. Carbon dioxide (CO2). Water spray. Alcohol resistant foam.
Large Fire: CAUTION: Use of water spray when fighting fire may be inefficient.
Unsuitable extinguishing media: Do not scatter spilled material with high pressure water streams.
5.2. Special hazards arising from the substance or mixture
Specific hazards arising from the chemical:
5.3. Advice for firefighters
Special protective equipment and precautions for fire-fighters:
Risk of ignition. Keep product and empty container away from heat and sources of ignition. In the event of fire, cool tanks with water spray. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.
6.1. Personal precautions, protective equipment and emergency procedures
Personal precautions: Evacuate personnel to safe areas. Use personal protective equipment as required. See
section 8 for more information. Avoid contact with skin, eyes or clothing. Ensure adequate ventilation. Keep people away from and upwind of spill/leak. ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Pay attention to flashback. Take precautionary measures against static discharges. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material.
Other information: Ventilate the area. Refer to protective measures listed in Sections 7 and 8. For emergency responders: Use personal protection recommended in Section 8.
6.2. Environmental precautions
Environmental precautions: Refer to protective measures listed in Sections 7 and 8. Prevent further leakage or
spillage if safe to do so. Prevent product from entering drains.
6.3. Methods and material for containment and cleaning up
Methods for containment: Stop leak if you can do it without risk. Do not touch or walk through spilled material. A
vapor suppressing foam may be used to reduce vapors. Dike far ahead of spill to collect runoff water. Keep out of drains, sewers, ditches and waterways. Absorb with earth, sand or other non-combustible material and transfer to containers for later disposal.
Methods for cleaning up: Take precautionary measures against static discharges. Dam up. Soak up with inert
absorbent material. Pick up and transfer to properly labeled containers.
Prevention of secondary hazards: Clean contaminated objects and areas thoroughly observing environmental regulations.